Monday, November 8, 2010

Wednesday, October 27, 2010

Testing Procedure

Usage Test

When docking or fueling at our marina, our patrons will be asked to fill out a short survey:

1) What is the size of your boat and how much fuel did you intake?
2) Were our fuel attendants friendly and able to answer any questions you had?
3) How satisfied are you with the speed of service at the fuel station?
4) Are there any areas in which improvements could be made?
       If so please explain: 


Observation Test

Fueling station should be examined under the following:

1) Fuel tanks are resistant to degradation form weather (not weathered color).
2) Piping is out of the way of regular movement of traffic.
3) Fuel dispensers are easy to get to (maneuverability around tank).
4) Berm is stable and not cracked
5) Support poles for roofing are stable and roof is sturdy.

Saturday, October 16, 2010

Alternate Solutions

Alternate Solution 1

This alternate solution uses two horizontally lain polypropylene fuel tanks.  The first tank has a volume capacity of 8,000 gallons which will store gasoline while the other has a capacity of 10,000 gallons which will store diesel fuel.  Only one tank can be used at a time based on this solution.  The pipes are made from polypropylene as well due to its resistance to the natural elements.  The width of the plot for my fueling station is 50 feet while the length is 80 feet.  The paved surface is sloped towards the southwest corner into a drainage system.  





Alternate Solution 2

This alternate solution uses two horizontally lain polypropylene fuel tanks.  The first tank has a volume capacity of 8,000 gallons which will store gasoline while the other has a capacity of 10,000 gallons which will store diesel fuel.  The positioning of these tanks on opposite sides of the fueling station would make it more costly to enclose the tanks to protect them from degradation.  Only one tank can be used a a time.  The length and width of the plot are 80 feet and 50 feet respectively.  The plot drains to the north center section.



Alternate Solution 3

This solution uses two vertical steel fuel tanks.  Both tanks have a capacity of 10,000 gallons.  The positioning of these tanks would be optimal if one wanted to enclose the tanks because they are close together.  These tanks also take up less space than traditional fuel tanks.  Both tanks can be used simultaneously making the station more efficient.  The length and width of the station are 60 feet and 40 feet respectively.  The plot drains towards the northern center of the station. 



Thursday, October 14, 2010

Rationale

Alternate Solution 1 Alternate Solution 2 Alternate Solution 3
pastedGraphic.pdf pastedGraphic_1.pdf pastedGraphic_2.pdf
Material must be durable to elements - - +
Material must have long product life + + -
Containment berms must be set around tanks with at least 1.1 times the capacity of the fuel tank S S S
Fuel tanks should be easily accessible to multiple users - - +
Space for tanks should not be large - - +
Waste and spill runoff drain should be close to dispensary + - +
Berm should be efficient (not use too much concrete) + - +
Total 3 -3 5
Rank 2nd 3rd 1st  
My first viable solution uses one 10,000 gallon and one 8,000 gallon fuel tank for holding diesel and gasoline respectively.  The tanks are lain side by side to make it easier to contain fuel if it is spilled.  Both tanks are made out of polypropylene and are lain horizontally.  Polypropylene is a very long lasting material but is prone to degrade due to oxidation and UV rays which are prevalent at a marina.  One tank will be able to be used at a time which is not very efficient.  The drainage system is located very close to where fuel is dispensed which decreases the chance for fuel to wash off onto the soil.  Because the tanks are lain side by side, building a berm would be efficient in the use of concrete.  This solution ranks second out of three.  
My second viable solution uses one 10,000 gallon and one 8,000 gallon fuel tank for holding diesel and gasoline respectively.  The gasoline tank is in the northwestern part of the station while the diesel tank is located in the northeastern part of the station.  Both tanks are made out of polypropylene and are lain horizontally.  Polypropylene is a very long lasting material but is prone to degrade due to oxidation and UV rays which are prevalent at a marina.  One tank will be able to be used at a time which is not very efficient.  The drainage system is located in the northern section of the station, away from the nozzles for the fuel.  Because the tanks are separated from each other, building berms for each tank would use more concrete than in necessary.  This solution ranks third out of three.   
My third viable solution uses two 10,000 gallon tanks for the gasoline and diesel.  The tanks are located at the northern center of the station.  The tanks are made out of steel and are vertical.  Steel is very resistant from the corrosion by fuels oils but rusts over time making it less viable than plastics for long term use.  Both tanks can be used simultaneously by two separate vehicles making it efficient in that regard.  The drainage system is located almost directly next to where the fuel is transferred at the fueling station.  The berm for this station is the optimal choice because its design uses the least  concrete.

Wednesday, October 6, 2010

Summer Research and Brainstorming


Introduction

My task is to design a fueling storage and delivery fuel line system for an environmentally friendly marina on Sandy Hook.  Fuel is the one entity that allows almost everything around us move.  Fuel such as coal powers industrial plants which produce objects we use in our everyday life.  Some plants also generate electrical power by burning coal.  Cars, buses, schools and nearly everything we come into contact with relies on fuel based power.  Marine boats are one of the many consumers to fuel.  Fuel oil is produced from the distillation of crude oil.  The distilled object is burned in anything from a furnace to the engine of a car and produces enough energy to sustain each object capacitance.



Situation


Sandy Hook is a popular attraction for both tourists and locals.  Sandy Hook has beaches, along with many species of flora and fauna including over 300 species of birds such as osprey and Canadian geese.  Sandy Hook hosts a Coast Guard Base and even a branch of the National Oceanic and Atmospheric Administration: the Northeast Fisheries Center.  Fort Hancock, a former US Army fort, is also located on this six mile long peninsula.  Even with all these attraction, Sandy Hook is missing one thing, a marina.  Although three sides of Sandy Hook are surrounded by water, a marina for tourists and locals alike has not been built.  Because Sandy Hook is a Gateway Recreation Area and a part of the National Park System, if a marina were to be built, it would have to be environmentally friendly. 

My task in designing an environmental friendly marina is the land-based fueling station.  My fueling station will have to safely store fuel and transport make it available for use by boaters, both at our fueling dock as well as directly from the fuel tanks. 

Climate

Sandy Hook is a peninsula in the Northern Atlantic Ocean.  Ocean spray is an issue that must be dealt with when designing a fueling station.  Piping as well as the fuel tanks themselves can be degraded by the salt in the ocean.  Rainfall and precipitation such as snow are also factors in degradation.  Snow can cause the fuel to freeze if it is piled up next to the tank. 

Conditions of Use

The use of the station on land would be minimal.  Most people will either fill up at a dock when their boat is already in the water or they will fill up at a gas station where the prices are usually cheaper compared to those at a marina.  Patrons who do fill up at our marina, will fill up using pumps coming directly from the tank.  The fuel must be able to be contained if it is spilled and disposed of properly.

End User

Mostly boaters who are putting their boat in the water from our docks will use my fueling station.  Also, some boaters will want to fill up backup fuel canisters for their boat in case of an emergency.  The station could also be used by patrons and employees who want to put gas or diesel in their vehicle’s tank.  

Brainstorming

Piping
·      Polypropylene, PVC, and steel piping/all viable options
·      Steel is more effective in retaining fuel in terms of degradation of material
·      Both PVC and polypropylene would last longer, steel rusts and degrades much more quickly over time than these thermoplastic polymers
·      Steel piping would have to be welded to change direction of flow
·      PVC and polypropylene have premade joints to change direction of flow
Piping comes in various shapes and types from simple plastics to steel and other strong metals.  The usefulness of piping can be determined by the make up of its components.
When looking at the components, the chemical strength of the material is the most noteworthy.  Different types of piping are used all around the world, homes receive water from underground piping and even banks use piping to send checks and deposit slips to and from convenience drive through stations at banks.  Choosing what type of piping should be used is as easy as knowing what you want to pass through the pipes as well as the chemical strength the pipes have against your chosen fluid.  

Tanks
· Polypropylene and steel tanks are used in the boating industry
· Polypropylene degrades from oxidation and from exposure to UV rays (both of which are an issue considering this is a marina!)
· Steel however, rusts as all metals do, decreasing its shelf life (so to speak)
· Above ground tanks will be exposed to the weather and sea spray, but easier to maintain, tanks and pipes
· Below ground tanks take up virtually no above ground space and is not exposed to weather conditions, but are harder to maintain because the tank would have to be dug up to examine it (examined for leaks, damage, etc.)
I plan to have a small plot of paved land that patrons can fill up tanks on.  The plot would be paved and would be sloped inwardly, so that any spilled fuel will run off into either a removable steel drum or a piping system. 


Fuel tanks can vary in sizes from small 30-gallon tanks all the way up to 500,000-gallon fuel tanks used by NASA.  Fuel tanks can be made out of any material that does not easily degrade from either corrosion from the fuel it is holding or the elements which it encounters on a regular basis.  Tanks can be installed above ground or even below ground so there are many possibilities.   

Fuel is classified into six classes based on its boiling point, its chemical make up and its weight.  The different classes of oils have their own unique uses.  The oils which will be provided for marina patrons are both Number 2 type oils.  Marine diesel oil (MDO) and marine gas oil (MGO) are used by boats from 0-90 feet long.  Most boats from 0-50 feet long require marine gas oil to run their engines. MGO is highly flammable and can be extremely dangerous.  Its high risk for explosion is not the only thing which makes it dangerous; because MGO is very light, it often mixes well with water and is very harmful to fishes and other animals that come into contact with it.

Marine diesel oil is most often used in boats larger than 50 feet long. Diesel dumping is a cause of some acid rainfalls.  Diesel contains a high level of sulfur which is harmful to marine environments because when it reaches water, it becomes sulfuric acid which causes acid rainfall.  Diesel is safe when exposed to heat.  A match can be dropped directly to a barrel of diesel and all that will happen is the match will go out.



10/06/2010 Log

Monday:  Created a calendar of events and due dates, Began to fix completely off base Summer Research and brainstorming

Wednesday (Today): Updated Summer research and brainstorming,