Friday, January 21, 2011

STEMM


Green Marina Fueling Station STEMM Process
Michael Rubens
Introduction
Text Box: Figure 1: Fueling Station CAD drawingAD-STICK:Senior Project Green Marina:Front View Conc Slab.JPGMike is responsible for the design and installation of two 10,000-gallon fuel tanks on the marina property located on Sandy Hook.  Spills of oil and gasoline affect the environment in many ways causing damage to plants and animal life and the eco-system as a whole.  The primary problem is to avoid catastrophic fuel leakage into the environment in the event of a failure in the system.  Mike has designed an environmentally friendly fuel storage system that incorporates leak detection and spill containment.  The fuel system consists of two 10,000-gallon fuel tanks situated on a concrete pad and enclosed in a concrete berm area.  The capacity of the berm containment exceeds the 20,000 gallons stored within.  Piping from the tanks to the dock is of double walled construction and has multiple sump systems at each low point.  There is also a roof to mitigate the effects of direct sunlight on the tanks and aboveground parts of the piping system.  There will be electronic leak detection that will be monitored by the dock attendant.  (See Figure 1 for CAD drawing of fueling station)
 
Engineering
The design of Mike’s fueling station and piping system are innovations as opposed to inventions.  An invention is defined as an original product that has not been designed for a specific purpose.  Conversely, an innovation is a product that has been designed to a set of parameters.  In other words, it has been designed for usage in a defined purpose.  Mike’s fueling station design is considered an innovation because I designed it to a set of specifications and limitations.
Mike’s design is a closed, technological system and mechanical system.  The tanks are a component of the fueling station that uses a ventilation system.  This system siphons air into and out of the tank, keeping the fuels inside the tanks at a low pressure.  A ventilation system is vital because an increase in pressure is directly related to an increase in heat, which for fuel is a very dangerous thing.  Mike’s design is a closed system because its output is based solely upon the internal components of the system and does not include outside factors. 
Types of Engineering
The types of engineering that are involved in the design of the fueling station and fuel transport system are electrical and structural engineering.  Electrical engineering is relevant to the design because both the tanks and the sumps require electricity to set off an alarm.  The tanks will be outfitted with fuel monitoring sensors that will measure the amount of fuel in the tanks as well as sound an alarm at the fuel attendant hut on the dock to signify a leak in the tank.  The sumps utilize both electrical and mechanical engineering.  The sumps are outfitted with a liquid senor, a ball valve, a solenoid valve and a safety break.  The liquid sensor is linked to the safety break, which is tripped when it detects a liquid in the sump and closes itself off, isolating the leakage.  The normally closed solenoid valve is connected directly to the pump by way of electrical wiring and is opened and closed with the turning on and off of the fuel pump motor. 
Structural engineering is relevant in the design of the concrete berm and concrete slab.  The depth of the concrete slab is designed bearing in mind its maximum weight capacity.  Two full tanks of product and the weight of the roofing structure are taken into account.  The slab is the fundamental base structure for the entire fueling station.  The berm is designed to contain 110% of the maximum product in both fuel tanks.  The berm’s thickness is designed to make sure that it will stay standing and will not be flimsy and topple under uneven weight. 
Types of Manufacturing
The three types of manufacturing associated with the design are mass production, fabrication, and prefabrication.  Mass production is the fast production of standardized products, typically on an assembly line.  CPVC piping is made in various girths and lengths and is mass-produced.  The fuel storage tanks produced made though prefabrication manufacturing.  Prefabrication manufacturing is the process of assembling components of a structure at an offsite location from where the product will be utilized.  The sumps and their components will be fabricated.  This process of manufacturing consists of creating the separate components offsite and then assembling them onsite. 
Science
 Scientific laws are the fundamental definitions of why everything in the world works.  One scientific law related to the project design is the law of gravity, credited to Sir Isaac Newton.  The law of gravity states that all objects on Earth are attracted to its center.  Figure 2 shows the action of gravity.  This law is exemplified in the design by the placement of the sumps.  Because everything gravitates downward, the sumps are placed at the low points in the piping system if they are at a lower altitude than the fuel tanks.  Another related scientific concept is Gay-Lussac’s law.  This law states that as the temperature of a gas increases, pressure decreases.  The only problem with this is that the law only takes into account an open system where the volume of the gas has space to increase.  In a closed system, when temperature rises its pressure also rises.  When molecules have less space to move, their speed increases; this reaction causes the internal temperature of the system to rise.  It is for this reason that the tanks are outfitted with ventilation points so as to keep both the temperature and pressure inside of the tanks as low as possible. Figure 3 shows the original aspect of Gay-Lussac’s law.  Boyle’s law states that the pressure and volume of a gas at a constant temperature are inversely proportional.  In regards to the fuel piping system, when the pump on the dock is turned on, the pressure inside the tank is increased, causing the fuel to run through the only available open space, C:\Documents and Settings\Marilynn\Desktop\images.jpgthe pipes.  Figure 3 is also relevant for Boyle’s law.


Text Box: Figure 2: Gravity
C:\Documents and Settings\Marilynn\Desktop\glussac.gifText Box: Figure 3:  Relationship of temperature and volume



Technology
Text Box: Figures 4-1 though 4-4: Sump componentsMacHD:Users:student:Desktop:Permit083.jpgTechnology that is incorporated into the design of Mike’s fueling station allows the fueling station to function efficiently and effectively.  Such pieces of technology are liquid leak sensors, ball valves, solenoid valves, safety breaks, an emergency shut off switch, overfill protection devices and ventilation systems inside the tanks.  Liquid leak sensors are installed into sumps to monitor if any product is leaked inside of the piping.  Ball valves are part of the containment sump systems that are manually operated valves that cut off the flow of product in piping.  The solenoid valves, also known as anti-siphon valves, are used to remotely cut off piping so product cannot flow further down the pipe system.  The solenoid valve is linked to the emergency cut off switch so that when the switch is flipped, the valves seal themselves off, keeping product from flowing further towards the pump.  The safety breaks are included in the shore to dock transition sumps.  The safety breaks are intended to protect piping from damage when the movement of a floating dock exceeds its design limits.  All four components of the sump are visible in
Figure 4.
Mathematics
Text Box: Figure 5: Maximum Weight of tanks and pressure per square footMacHD:Users:student:Desktop:Permit081.jpgThe mathematical computations involved in the design of the fueling station solve for the Maximum weight of the tanks, the measurements for the roof and calculations for the size of the berm surrounding the tanks.  The maximum weight of the tanks in pounds is equal to the weight of the fuel per gallon multiplied by 10,000, its maximum storage capacity in gallons.  After adding 2,000 pounds for the shell of the tank, Mike divided the total weight of each separate tank by the surface area of the bottom face of the tank.  These calculations are shown on Figure 5.  The next calculation solves for all the sides of the roof, and most importantly the height between the top of the tanks and the roof.  This is shown in Figure 6.  The slope of the roof is 6/12, which equates to an angle of 26.57 degrees.  Mike used trigonometry to find the other angle and sides of the roof.  The horizontal distance between the end and center of the roof is already known, allowing the rest of the right triangle to be easily solved for.  The third set of calculations solves for dimensions of the berm enclosure.  The volume of the berm must have the capacity to contain 110% of the maximum capacity of the tanks while taking into account the volume that the tanks displace, shown in Figure 7.

Text Box: Figure 6: Calculations for dimensions of roof

MacHD:Users:student:Desktop:Permit082.jpg




MacHD:Users:student:Desktop:Permit080.jpgText Box: Figure 7: Berm calculations (including displacement of space by tanks)

Conclusion
Mike’s design is a closed technological and mechanical system.  It uses both electrical and structural engineering for its construction.  The manufacturing processes involved with the fueling station design are fabrication, prefabrication and mass production.  The most significant technology incorporated into the design is the sump system.  The most relevant scientific concept related to the fueling station is the interpretation of Gay-Lussac’s law.  The most important mathematical calculation is that of the containment berm.  The final fueling station design utilizes two aboveground tanks with a containment berm and roof with underground piping (with sumps at low points in the piping) that leads to the fueling dock. 


Monday, January 17, 2011

Environment for project

Aerial view of site map

CAD Drawings

Back View Fueling Station  (no pipes)

Back View Fueling Station

Double-walled piping and sumps

Front View Fueling Station

Side Right View Fueling Station

Top View Fueling Station (no roof)

Gas/Oil spill problem

Oil Spill effect on animal life

Gas spill effect on marine environment

Model Pictures

Overview
Aerial view of tank area

View of tank area from dockside

Note sump access

Subterranean view showing piping and sumps

Friday, November 26, 2010

Log 11/ 26/10

  • Reconfiguring size of berm, using calculations as well as in CAD
  • Updating table of materials: concrete and tanks
  • Researching piping types/composition

Wednesday, November 24, 2010

Log 11/24/10

  • Continued creating fueling tanks and berm for CAD drawings
  • Researched parts of concrete mixture