- Continued work on exhibit presentation
Thursday, February 24, 2011
Tuesday, February 22, 2011
Log 2/22/11
- Started work on poster
- Continued small tweaks of CAD drawing
Wednesday, February 16, 2011
Log 2/16/11
- Added dimensions to left side
- Continued creation of sump in 3D
Monday, February 14, 2011
Log 2/14/11
- Added dimensions to side and top view in 2D wireframe
- Started drawing sump and components in 3D
Friday, February 11, 2011
2/11/11 Log
- Today I worked on adding dimensions to my CAD drawing in 2D wireframe
- Otherwise I did not do much
Thursday, February 3, 2011
Log 2/3/11
- Monday-Wednesday: I was taking midterms and was not able to work in class
- Today I was researching installation methods for concrete and roofing supports
Friday, January 28, 2011
Mentor contacts
12/22/10
Brian Holderness
I called Brian to inquire whether or not there was a standard for concrete slab installation and construction
12/23/10
Mike,
Sorry, I forgot to attach the document with the tables, etc. Here it is...
BTW- Additional considerations would be the force of the perimeter wall (lds/linear ft), soil type if different from assumption (gravelly sand), and the frost line (New Jersey?). 14" should be sufficient to address these additional considerations, but you should probably note them as variables that you considered.
Sorry, I forgot to attach the document with the tables, etc. Here it is...
BTW- Additional considerations would be the force of the perimeter wall (lds/linear ft), soil type if different from assumption (gravelly sand), and the frost line (New Jersey?). 14" should be sufficient to address these additional considerations, but you should probably note them as variables that you considered.
From: holdernessfamily@msn.com
To: msrcali@aim.com
Subject: Concrete slab thickness
Date: Tue, 21 Dec 2010 19:04:04 -0500
Mike,
Here are my rough calculations for the thickness of concrete required to support a tank(s):
d=11.25 ft
h=13.5 ft
A * h = 17.66 * 13.5 = 238.4 cu ft
Assuming tank is full of water @ 62.4 lbs/cu ft = 14876 lbs over a base of 17.66 ft or 842 lbs/ft2
Using Table 3-1 in the UFC Concrete Floor Slabs On Grade Subjected To Heavy Loads and assuming 600 lb/in2 flex strength concrete, h (inches) of concrete slab = 6
Factoring for Gravely Sands ( as typically found near marine environments) of low moisture content (gravely sand does not retain moisture well) from Table 4-1, I will use a modulus factor of 300. Returning to Table 3-1 notes, a modulus of 300 yields a constant factor of 1.7. 842 lbs/ft2 * 1.7 = 1445 lbs/ft2.
This equates to 14" of 600 lb/in2 flex strength concrete. This depth can be significantly reduced using reinforced concrete, but I can live with 14".
Hope this helps,
Brian
=
11/29/10
Mr. Danko
Mr. Danko visited our class to say, and to answer any questions we might have had (separate group members)
Above –ground tanks/ make sure they are double-walled
· Possibility of using a concrete vault (enclosure) for tank
· Containment berm: 110% of truck capacityà disproven by Clean Marina Requirements
· Speed bump and room for truck on concrete should be included
12/15/10
· Construction firms that build marinas
· 100+ feetà worry about sea spray
12/15/10
Charles Pistis @ 2:20 PM
Michigan Sea Grant
I called Mr. Pistis to inquire about the process for installing concrete near water, I was assuming standardized practices would not change dramatically between states
· Best practice
o Civil engineer with specialization in concrete pads of gas stations
· In Michingan: DNRàDepartment of RecreationàWaterways division
· Was sent list of civil engineering firms by Mr. Pistis (Attatched)
h212/25/10
Brian Holderness
Brian was at my friend's house on Christmas morning so we discussed the feasibility of different types of concrete on the sandy soil.
- Reinforced concrete would reduce the amount of concrete needed for the slab because of its strength
- In order for the slab to be built, i would have to dig into the soil before setting supports for the mold